medical waste PYROLYTIC INCINERATOR

TECHNICAL SPECIFICATIONS: PYROLYTIC INCINERATOR

Parameter Compliance
Type of Waste To treat medical waste, categories A,B,C,D,E
Type of Incinerator Pyrolytic
Nominal Burn rate 50 t0 60 kg/ hr at 3500Kcal/Kg
Loading Manual, Batch Load
De Ashing Automatic or Manual batch de ashing
The incinerator must avoid the release of black smoke and fine dust during the loading
Primary chamber capacity 2-3 m³
The insulation   of the combustion chamber should be composed   of refractory bricks, having a higher content of aluminium and insulates,
The plate of combustion in carborundum avoiding the fixing of glass and slags
Hours of operation /Day >10 hrs
Max Operating Temperatures 1400 °C
Normal Operating Temperatures(Primary) >850 °C
Operating Temperature(Secondary) >1100 °C
It should have digital temperatures regulator( Temperatures regulator in digital watch)
Carbon content of ashes <2%
The installation should be completely free from visible smoke as well as offensive odours
Residence time in second chamber 2 second minimum
The internal diameter of the Chimney :Ø 400
Height of stack >8m
Burner operation Automatic On/Off
Fuel Diesel
Fuel consumption at raed capacity >7kg waste /ltr
Electricity consumption <2kW at rated capacity
Operating Voltage 220 – 240V AC 50Hz
Spare parts Supply for 1 year quoted as option
Consumables Supply for 1 year of operation to be mentioned as option
Warranty Parts and service support: 1 year minimum post comissioning
Service support <72 hours
Emission standard Compliance BS3316 or equivqlent standard
Process filtering system Scruber to be mentioned as option
CE Manufacturing Compliance BS EN 746-2-1997
Design Specification Type A,B,C,D,and E of medical waste
Installation and Comissioning Included in condition of supply
Training in preventive and curative maintenance and use of the incinerator Operator training inclusive in offer
Capacity to treat Plastic Not less than 40% by weight

 

Categories:

Recent Posts