250kgs per hr Capacity waste incinerator

A room of post burning of gases

* A heater of burning of gases,

is dual/double combustion chamber with 02 units oil burner, batch load incineration equipment. 
Waste feed chamber is 1800Liters (1.8m3, TS250 PLC). Primary & Secondary combustion chambers
and smoke filter chamber. Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation. 

* A device of shot of atmosphere allowing an entire recombustion of gases,

* An instrument of air ducts of air conditioning of waste gases, including

* A sheath of emptying of the gases charred.

* Carcass in solid sheet steel with assistance of link.

* Construction of the refractory;

・ Refractory concrete:

§ Thickness: ≥ 150 mm

§ Character: 65 percent of Al203

・ Protect in primitive panel:

§ Thickness: ≥ 85 mm








Character: Calcium

Burner Model TS250 PLC, Review

This layout is small waste incineration tools for little waste outcome. Construction

Main Product List per 01 collection

Primary Burning Chamber

Added Combustion Chamber

Smoke Filter Chamber

Incinerator PLC Control Instance

Smokeshaft:10.0 Meters

*( upgrade to Stainless-steel, complimentary cost )

Italy oil/gas heater: 02 units

Oil Tank (if petroleum fuel): 300Liters

Items/Model

TS200( PLC)

Picture

Principle

Strong Waste Incineration Therapy

Burn Speed

Average 250 kg/hour

Feed Capability

Standard 350kg/feeding

Control Putting

PLC( Programmable Logic Controller Burner)

Combustion Chamber

1800L

Internal Measurements

150x110x110cm

Second Chamber

750L

Smoke Filter Chamber

Yes

Feed Mode

Handbook

Voltage

220V

Power

0.9 Kw

Oil Intake (kg/hour)

Ordinary 28

Gas Utilization (m3/hour)

Typical 33.6

Temperature Level Screen

Digital Present

Temperature Level Security

Yes

Oil Tank

300L

Feed Door

80x60cm

Smokeshaft

10Meter

Smokeshaft Kind

Stainless-steel

1st.

Gross Weight

8500kg

Exterior Dimensions

300x160x190cm

Heater procedure should be Automatic On/Off

Gas: petrol

The vendor must provide required information for the finest of the installation

This incineration using “PYROLYTIC” combustion need to possess:

;

・ Refractory concrete:

§. Density: ≥ 100 mm

§. Nature: 42% of Al203

・ Shield in primitive panels:

§. Thickness: ≥ 75 mm

・ Character: Calcium silicate.

* Burner of light of waste, together with gas, common mono-bloc casting directing diving fire, lights along with safety of electronic ignition, irreversible air flow, electro-magnetic sluice entrance of regulation in addition to isolating valve.

* Plate of burning Carborundum, avoiding the dealing with glass in addition to slags.

§ Nature: 65% of Al203

・ Protect in coarse panel:

§ Thickness: ≥ 85 mm

Nature: Calcium