Best Feeding Door HICLOVER 10-500kgs/Hr.Double Combustion Chambers Waste Incinerators

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

HICLOVER is currently offering a broad range of medical waste incinerations, designed to provide efficient waste destruction, utilizing best available technology and environmentally friendly procedure. On account of the secondary room with its 2 second retention period, our medical incineration range is well suited to process medical waste.

 

Our products ensure effective, clean and easy disposal of medical waste is possible. The incineration of clinical waste including pathological waste (red bag waste), Biohazards & Sharps, General Medical Waste, by Hospitals, Research Center, Pharmaceutical Companies, Medication Manufactures, Primary Care Trusts, Cosmetic Surgery Clinics, Nursing Homes, Care Homes and other Clinical Waste.


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Speed (Typical )

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Electricity

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Infection Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Feed Door

80x60cm

80x60cm

 

 

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Form

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm


Type of waste: medical and industrial (solid and semi solid hazardous)
Type of waste : Bio-medical & Hazardous (Solid and Semi Solid) 
If you are a hospital then Please also tell how many bedded hospital : No aren’t a hospital 
Quantity of waste generated per day in kg : 6000 kg
Duration C incineration will be used per day :1 C 16 hours 
Approximate moisture content: 47 to 53%
Availability of power and type : 3 Phase, 440 Volts
Details of space available : Min. 10000 Sq.  ft.
Do you require an automatic loading system? Depends if it is a continuous burning or interval burning.
How soon do you require the system to be delivered? 8 weeks
Whether the location is a coastal area : No
An other specific requirements: Automatic PLC Control System.
Burning Rate: 500kg/hour
Volumetric capacity Primary Chamber: 500kg
Burner Type: Diesel Operated
Burning Process: Continuous

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator