Basic Info.
Product Description
Technology Respond(FAQ)
Q: What’s kind of waste may utilize within this equipment? A: This equipment for medical waste, pet creature, Municipal waste, live waste. Prohibit any volatile and radiation substance, liquid waste and gas waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001.
Q: Treatment capacity A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not indicate any waste material. The animal/pet combustion speed around 2/3 of average power.
Clover incineration utilize time per day up to 24 hours. Between every feed/combustion time, you will find about 0.5-1 hours cooling time plus time to get feeding waste. Actual combustion time daily is around 16 hours. The life of incineration involving 5-10 year based on use.
Ordinarily, we proposal little laboratory, little clinic use capability under 20 kgs per hour. When incineration utilize in hospital, then please calculate the waste output capacity around 2kgs per individuals per day. If there are 200 sickbed in the hospital, that's imply you need 1 incineration capability around 400kgs per day, switch to capability per hour is around 30-40 kgs per hour. According the performance time per day, waste material, funding, development, etc, you may use capacity from 30-50 kgs per hour incineration. *The best way to calculate Animal Cremation Burn Rate: 2/3 of this medical waste.
Q: Meeting and Testing A: We supply all files and incinerations simple to installation and functionality. Small scale medical incineration, smart ash incineration, 30 kg per hour-incineration, creature incineration for sale, incinerations, incinerations for sale, Customer can send individuals visit our factory to learn installation and operation. Generally, we don’t send engineer to neighborhood website if not request. The dispatch cost is extra based on order. The second combustion chamber: 1000-1200 centi degree.
Q: Incinerator Control Mode A: Default Control mode is common control instance. PLC mode based on order and model.
Q: Operation and maintenance costs A: Operation cost based on fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD per year maintenance according version, use situation.
One individual can service 02 unit incinerations. The staff should have fundamental electrician knowledge to operate/inspect/maintaince incineration/burner/blower based on performance user guider, and know risk of medical waste to protect worker self with necessary protection component.
Q: The Residency period in combustion chamber A: 02 sec.
Items | Specification | ||||
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Model | TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC) | ||||
Main Product List | Double Combustion Chamber | ||||
Smoke Filter Chamber | |||||
PLC Mode Control Case | |||||
Stainless Steel Chimney | |||||
Italy oil/gas burner: 02 units | |||||
Oil Tank (if oil fuel) |