Doors
The doors shall be hinged on the ideal hand side and can be readily opened and shut. All doors shall be manually
operated. Incinerator will NOT incorporate automatic doorways. All doors should be internally lined with pre-determined
thickness insulation and refractory cement.
Stack
The stack shall be fabricated from pre-determined thickness stainless steel plate appropriately flanged for connection.
Combustion Air Blower
A combustion air blower shall be of steel building type with built-in air damper regulation shall be provided. The
impeller will be of those radial blade layout and all rotating elements shall be dynamically balanced.
Burners
Burners fitted will be of packaged fuel oil fired types. Principal chamber shall be fitted with an on/off form burner
while the secondary chamber shall be fitted with a high/low form burner. The burners shall each have a highest score
of300,000 kJ/hr.
Controls
A control system will be provided to control all functions of the main and secondary chambers including combustion
air distribution and burner control. It will contain of PLC, temperature controllers, timers, relays and switches to
provide automatic functioning of the full system. All switches and controls shall be mounted at an IP 55 rated control
panel.
Power Supply
The incinerations will have a power source of 240/415 volts, 50 Hz AC.
Rules SA 3000 and be subject to PNG Power regulations.