hiclover.com macau pet cremation incinerator

Presently, we supply different series for local customer requirements and design 

updated incinerator with our leading technology. The updated design feature 
of our range of incinerators make them one of the most cost effective in the world.
Key Features:
* All models with Dual combustion chamber. 
* Stainless Steel chimney/stack, long lifetime. 
* High temperature, long lifetime of incinerator.
* Free or minimum installation on site.
* High burn rate, from 10kgs to 600kgs per hour, up to 10ton per day.
* PLC Control Plane for Intelligent operation. 
* New Design for pet animal cremation business.
* One year warranty on incinerator and parts in stock.

It features unique and advanced merits with compact size, high burning effect, 
reasonable burning technology, high degree of non-harm etc.It is an ideal 
choice for waste treatment of hospitals, hotels and various areas.

Features:

(1)   Gasifiedpyrolysis incineration is used for burning many kinds of waste.
(2)   Waste can be burned once everyday by gasified incineration.
(3)   Gasified incineration, mixed incineration and burnout treatment ensures low emission standard of dust,dioxin etc.
(4)   Totally enclosed operation is suitable for treating infectious waste to avoid secondary pollution.

(5)   Compact structure and small land occupation.
WWW.HICLOVER.COMWaste Incinerators Auto Roll Air Filters
Nanjing Clover Medical Technology Co.,Ltd.

Tel:  +86-25-8461 0201   

Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: sales@hiclover.com
Email: hicloversales@gmail.com  
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000-1200 1000-1200 1000-1200 1000-1200 1000-1200
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

PRIMARY CHAMBER
Heavy-duty steel casing
High quality refractory lining and insulation Large full size top load counterbalanced door
1 x oil/gas fired ignition burners operated on/off

SECONDARY CHAMBER
Heavy-duty steel casing
High quality refractory lining and insulation 2 second gas residence time
1 x oil/gas fired ignition burners operated on/off

CHIMNEY
Heavy-duty stainless steel casing

CONTROL PANEL
Control of primary and secondary burners Temperature Monitoring with 4 digit display 

Thermostat control device for burner (fuel saver) Timer 
control 0- 12 hours
Integral fan timer control

ANCILLARIES
Operating and maintenance manuals Spares list

KEY FEATURES

•Afterburner Preheat

•Incineration temperatures in excess of 1300°C

•5mm steel casing and fully insulate

•Dense refractory concrete lining rated to 1600°C
 

An approved plant must have four distinct sections that demonstrate three principles of
Turbulence, Residence Time and Temperature are inbuilt in the plant design .

The regulated sections may include but not limited to:

Overall plant layout. Feed chamber/ charging
Primary Combustion Chamber. Secondary Combustion Chamber. Particulate Scrubbers
Acid Gas Scrubbers The stack/ chimney.
Controlled hygienic, mechanical or automatic feeding methods have to be used which
will not influence the air temperature in the primary and secondary chambers of the incinerator negatively.

No waste is to be fed into the incinerator:

1. Until the minimum temperatures have been reached.
2. If the minimum combustion temperatures are not maintained.
3. Whenever the previous charge has not been completely combusted in the case of batch feeding.
4. Until such time as the addition of more waste will not cause the design parameters of the incinerator to be exceeded.
The primary combustion chamber must:

1. Be accepted as the primary combustion zone.
2. Be equipped with a burner/s burning gas/fuel or low sulphur liquid fuels. 

Other combustion methods will be judged on merits.

3. Ensure primary air supply is controlled efficiently

4. Ensure minimum exit temperature is not less than 850oC
The secondary combustion chamber must:

1. Be accepted as secondary combustion zone.
2. Be fitted with secondary burner/s burning gas or low sulphur liquid fuel or any suitable fuel.

3. Ensure secondary air supply is controlled efficiently.
4. Ensure flame contact with all gases is achieved.
5. Ensure residence time is not less than two (2) seconds.
6. Ensure the gas temperature as measured against the inside wall in the secondary 

chamber & not in the flame zone, is not less than 
1100oC.
7. Ensure the oxygen content of the emitted gases is not less than 11%.
8. Ensure both primary and the combustion temperatures are maintained 
until all waste has been completely combusted
A mechanical particulate collector must be incorporated after secondary combustion
chamber for removal of particulate pollutants entrained in the flue gas stream. 
The particulate collectors may include any of the following or 
a combination thereof:
Cyclone separator Electrostatic precipitators Fabric filters