incinerator for medical waste

0.11 KW
– The hearth Has a stirring system of waste combustion is controlled swap;
POWER BURNER
– The entire installation will conform to European standards (EU)
– The sole combustion is composed of a refractory liner specifically designed to meet the thermal, mechanical and corrosive liquid waste requirements and molten glass;
‘ TEMPERATURES:
. Afterburner
– The design of this burner is similar to combustion burners;
* Insulation:
? Offer controlled guaranteeing the absence of colour, cloud of smoke or burning odor;
– Operating temperature:             1000 ° C maximum
– The dimensions of the floor are equipped laterally primary air nozzles that fuel combustion;
900 ° C
– Automatic monobloc burner and flame plunge equipped with a digital ignition system and permanent ventilation.
Mixed combustion chamber: 0.3m3
? The manual controls are provided on each individual item.
GENERAL SPECIFICATIONS:

The incineration for medical waste must be designated for the destruction of all kinds of waste produced by the middle for Health (waste type hospital, clinic, medical laboratory for destructive capacity of 30kg / h).

Pyrolytic gasification combustion control shall:

? Prevent development of black dust and smoke formation tine loading of waste;
– The burner ensures that a minimal temperature of 1100 ° C continuous;
Volume of combustion

chamber Combustion: 0.3 m3
Operation    12h/24, 6d / 7
? Allow limited fuel consumption

The incineration with pyrolytic combustion must contain:

a. Combustor:

– Chamber strong steel support legs sheet;
– The restoration operation of the ash will take place once a day line before starting the day’s operation.

Composition of the refractory lining:
Post combustion: 0.2m3
0.11 KW0

Fan power    0.37 kW

b. Post – combustion chamber:

– Heal the gas has a minimal temperature of 1100 ° C with a minimum residence time of two seconds the afterburner would be to;
– Operating temperature:             1650 ° C maximum
? Provide routine and complete combustion of the waste;
Combustion
– The lining is Made from refractory bricks and a thermal insulating material ensuring a minimum temperature of the sheet;
Air fan:
– The afterburner Has access doors in order to guarantee regular cleaning of dust;
– Thickness:                    110mm

Burner combustion:

– The combustion chamber is equipped with a burner to line to guarantee correct temperature to the Complete destruction of waste combustion;
– Character:                    Refractory bricks with 42 alumina
– A secondary air injection is anticipated and provides perfect oxygen content;
– The afterburner is lined with high thermal insulation with a depth of 150 mm

c. Cabinet, control and regulation:
– Regulators of fever with digital display:
– There is a motor operated valve which controls the flow in line with the combustion.
Chimney    Height: 5m, Diameter: 280mm

chamber Combustion: 0.3 m3
Post combustion: 0.2m3
Mixed combustion chamber: 0.3m3
` TEMPERATURES:
. Combustion
. Afterburner
900 ° C
1100 ° C
POWER BURNER
Combustion
Afterburner

0.11 KW
0.11 KW0

Fan power    0.37 kW