Q: what is kind of waste can use in this equipment?
A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit anyexplosive and radiation material, liquid waste and gas waste.Q: The Residency period in second burning chamber
not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity.Tel: +86 -25 -8461 0201
there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustiontime per day is around 16 hours. The lifetime of incineration between 5-10 year according to use.Clover incineration utilize time daily to 24 hours. Between every feed/combustion period,
When incineration use in hospital, please calculate the waste output capacity around 2kgsper people per day. If there are 200 sickbed in the hospital, that’s mean you need oneincineration capacity around 400kgs per day, change to capacity per hour is around 30-40 kgsper hour. According the operation time per day, waste material, budget,development, etc, you can use capacity from 30-50 kgs per hour incineration.
*How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste.Generally, we proposition small laboratory, small clinic use capacity under 20 kgs per hour.
can send people come to our factory to learn installation and operation. Generally,We do not send engineer to local site if not request. The dispatch cost is extra according to order.Q: Assembly and TestingAWe provide all files and incinerations easy to installation and operation. Client
Q: Combustion TemperatureA: The first combustion chamber: 800-1000 centi degree.The second combustion chamber: 1000-1200 centi degree.
Q: Incinerator Control ModeA: Default Control mode is common control case. PLC mode according to model and order.
Q: Operation and maintenance costsA: Operation cost according to fuel consumption rate and power/staff, etc.
Annual approximately $500-$1000usd per year maintenance according model, use situation.
knowledge to operate/inspect/maintaince incineration/burner/blower according tooperation user guider, and know risk of medical waste to protect worker self with necessary protection element.One individual can service 02 device incinerations. The staff should have fundamental electrician
A: 02 sec.Nanjing Clover Medical Technology Co.,Ltd.Q: The Residency time in secondary combustion chamber
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm Secondary Chamber 50L 110L 180L 280L 600L Smoke Filter Chamber Yes Yes Yes Yes Yes Feed Mode Manual Manual Manual Manual Manual Voltage 220V 220V 220V 220V 220V Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28 Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2 Temperature Monitor Yes Yes Yes Yes Yes Temperature Protection Yes Yes Yes Yes Yes Oil Tank 100L 100L 100L 100L 200L Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm Chimney 3Meter 3Meter 5Meter 5Meter 10Meter Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel 1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm
Tel: +86-25-8461 0201