Basic Info.
Product Description
Technology Respond(FAQ)
Q: What is kind of waste may use within this equipment? A: This equipment for medical waste, pet creature, Municipal waste, live squander. Prohibit any explosive and radiation material, liquid waste and gas waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001.
Q: Treatment capacity A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour)doesn’t mean any waste material. Incinerator price, incineration price for 50kg/hr produced in china, incineration producers, incineration small scale, incineration suppliers in china, incineration baths china, The animal/pet combustion speed around 2/3 of typical capacity.
Clover incineration use time daily to 24 hours. Between every feed/combustion time, there are approximately 0.5-1 hours cooling time plus time for feeding squander. Actual combustion time daily is around 16 hours. The life of incineration involving 5-10 year according to use.
Ordinarily, we proposal little lab, little clinic use capability under 20 kgs per hour. When incineration use in hospital, please calculate the waste output capacity around 2kgs per individuals per day. If there are 200 sickbed in the hospital, that's imply you need one incineration capability around 400kgs per day, switch to capacity per hour is approximately 30-40 kgs per hour. According the performance time per day, waste material, budget, development, etc, you may use capacity from 30-50 kgs per hour incineration. *The best way to calculate Animal Cremation Burn Rate: 2/3 of this medical waste.
Q: Assembly and Testing A: We supply all files and incinerations easy to setup and operation. Client can send individuals visit our factory to learn operation and installation. Generally, we don’t send engineer to local website if not ask. The dispatch price is extra according to order. The next combustion chamber: 1000-1200 centi level. PLC mode according to model and order.
Q: Operation and maintenance costs A: Operation price according to fuel consumption rate and power/staff, etc.
Annual approximately $500-$1000USD annually maintenance according version, use situation.
One individual can service 02 device incinerations. The staff must have fundamental electrician knowledge to operate/inspect/maintaince incineration/burner/blower in accordance with performance user guider, and understand threat of medical waste to safeguard worker self with essential security element.
Q: The Residency period in combustion chamber A: 02 sec.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |