Leading Waste Incinerator

Basic Info.

Model NO.:construction of fire brick incineration
Export Markets:Global

Product Description

Technology Respond(FAQ) 

Q: What is kind of waste may utilize in this gear?  A: This gear to medical waste, pet creature, Municipal waste, reside squander. Prohibit any volatile and radiation material, liquid gas and waste waste. 

Q: Incinerator Smoke Standard  A: China Government Standard: No. GB18484-2001. 

Q: Remedy capacity  A: Average Ability calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg a hour)doesn’t indicate any waste material.

Clover incineration utilize time per day up to 24 hours. Between every feed/combustion time, there are about 0.5-1 hours cooling time plus time to get feeding squander. Actual combustion time daily is about 16 hours. The lifetime of incineration between 5-10 year based on utilize. 

Ordinarily, we proposal little lab, little clinic use capability under 20 kgs per hour. When incineration utilize in hospital, please compute the waste output capacity around 2kgs per people every day. If there are 200 sickbed at the clinic, that's mean you need one incineration capability around 400kgs every day, switch to capacity per hour is around 30-40 kgs per hour. According the performance time every day, waste material, funding, growth, etc, you may use capacity from 30-50 kgs each hour incineration.  *The best way to compute Animal Cremation Burn Rate: 2/3 of the medical waste. 

Q: Assembly and Testing  A: We provide all documents and incinerations simple to installation and functionality. Client can send people visit our factory to find out operation and installation. Generally, we don’t send engineer to local website or even ask. The dispatch cost is extra based on order.  The second combustion chamber: 1000-1200 centi level.  PLC mode based on order and model. 

Q: Operation and maintenance costs  A: Operation cost based on fuel consumption rate and power/staff, etc. 

Annual around $500-$1000USD annually maintenance according version, utilize situation. 

One person can service 02 unit incinerations. The staff should have fundamental electrician knowledge to operate/inspect/maintaince incineration/burner/blower based on performance user guider, and understand threat of medical waste to safeguard worker self with necessary protection element. 

One person can service 02 unit incinerations. The staff should have basic electrician knowledge to operate/inspect/maintaince incineration/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element. 

Q: The Residency time in secondary combustion chamber 
A: 02 sec.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Categories:

Recent Posts