Product Description
Technology Respond(FAQ)
Q: What is kind of waste may use in this equipment? A: This equipment to medical waste, pet animal, Municipal waste, reside waste. Prohibit any volatile and radiation substance, liquid gas and waste waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001.
Q: Remedy capacity A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour)doesn’t mean any waste material. The animal/pet combustion rate around 2/3 of average capacity.
Clover incineration use time per day up to 24 hours. Between every feed/combustion time, there are approximately 0.5-1 hours cooling time plus time to get feeding squander. Actual combustion time per day is around 16 hours. The lifetime of incineration between 5-10 year based on use.
Ordinarily, we proposal small laboratory, small clinic use capacity under 20 kgs per hour. When incineration use in hospital, then please compute the waste output capacity around 2kgs per people every day. If there are 200 sickbed at the clinic, that's mean you need one incineration capacity around 400kgs every day, switch to capacity per hour is around 30-40 kgs per hour. According the performance time every day, waste material, funding, development, etc, you may use capacity from 30-50 kgs per hour incineration. *How to compute Animal Cremation Burn Rate: 2/3 of this medical waste.
Q: Assembly and Testing A: We supply all files and incinerations easy to setup and functionality. Customer can send people visit our factory to learn operation and installation. Small scale medical waste incineration, syc-30 incineration, waste incineration maker China, Ordinarily, we don’t send engineer to local site or even request. The dispatch price is extra based on order. The second combustion chamber: 1000-1200 centi level. PLC mode based on model and order.
Q: Operation and maintenance costs A: Operation price based on fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD annually maintenance according version, use situation.
One person can service 02 device incinerations. The team should have basic electrician understanding to operate/inspect/maintaince incineration/burner/blower based on performance user guider, and understand threat of medical waste to safeguard worker self with necessary protection component.
Q: The Residency time in combustion chamber A: 02 sec.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |