Basic Info.
Additional Info.
Product Description
Q: What is kind of waste can utilize within this gear? A: This gear to medical waste, pet creature, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid gas and waste waste. GB18484-2001. The animal/pet combustion speed around 2/3 of average capacity.
Clover incineration utilize time per day up to 24 hours. Between each feed/combustion time, you will find approximately 0.5-1 hours cooling time and time for feeding waste. Burning incenrator manufactuer, burning medical waste, burning waste chamber, purchase a portable crematorium, purchase a small incineration, purchase creature cremation systems, Real combustion time daily is about 16 hours. The lifetime of incineration involving 5-10 year based on utilize.
Ordinarily, we proposal small laboratory, small clinic use capacity under 20 kgs per hour. When incineration utilize in hospital, then please calculate the waste output around 2kgs per people every day. If there are 200 sickbed in the hospital, then which 's mean you need 1 incineration capacity around 400kgs every day, switch to capacity per hour is around 30-40 kgs per hour. According the performance time each day, waste material, budget, development, etc, you can use capacity from 30-50 kgs each hour incineration. *How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Meeting and Testing A: We provide all documents and incinerations easy to installation and functionality. Customer can send people come to our factory to learn installation and operation. Generally, we don’t send engineer to local site if not ask. The dispatch price is additional based on order. The next combustion chamber: 1000-1200 centi degree. PLC mode based on model and order.
Q: Operation and maintenance costs A: Operation price based on fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD annually maintenance according model, utilize situation.
One person can service 02 device incinerations. The team should have fundamental electrician knowledge to operate/inspect/maintaince incineration/burner/blower based on performance user guider, and know threat of medical waste to safeguard worker self with necessary protection component.
Q: The Residency time in secondary combustion chamber A: 02 sec.
Annual around $500-$1000USD per year maintenance according model, use situation.
One person can service 02 unit incinerations. The staff should have basic electrician knowledge to operate/inspect/maintaince incineration/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | YD-10C | YD-20C | YD-30C | YD-50C |
Burning Rate (kgs/Hour) | 10 kgs/Hr. | 20 kgs/Hr. | 30 kgs/Hr. | 50 kgs/Hr. |
Feed Capacity (kgs) | 40 kgs | 40 kgs | 50 kgs | 80 kgs |
Equipment Weight | 1200 kgs | 1200 kgs | 1800 kgs | 2200 kgs |
Primary Chamber (Liters) | 200 | 200 | 250 | 400 |
Secondary Chamber (Liters) | 140 | 140 | 140 | 140 |
External Dimensions (cm) | 170x140x160 | 170x140x160 | 170x140x190 | 180x160x200 |
Internal Dimensions (cm) | 55x55x65 | 55x55x65 | 55x55x85 | 70x70x85 |
Oil Tank(Liters) | 50 | 100 | 100 | 150 |
Door Opening (cm) | 38 x 48 | 38 x 48 | 38 x 48 | 45×55 |
Chimney (M) | 5 | 5 | 5 | 5 |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Secondary Chamber | YES | YES | YES | YES |
Mix-Combustion Chamber | YES | YES | YES | YES |
Smoke Filter Chamber | YES | YES | YES | YES |
Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Temperature Monitoring | YES | YES | YES | YES |