Equipped with Primary combustion chamber and a second Room for reburning Made to ensure complete
combustion of These gases Caused by incomplete combustion of inert gases in the chimney, Inside the Criteria
recommended by the World Health Organization;
- Equipped with temperature controller to adjust the air of the combustion of the waste, and fuel flow in the
burners of the firing Room and re-burning in order to conserve Energy when reached the “stead state” of Their
combustion Procedure;
- The control system must also be provided with an audible alarm in case of decrease in temperature. The
Feature of local power is three-phase 220/127V – 60Hz.;
- The natural circulation of the gases will be induced in a chimney height at least 6 meters and diameter of
at least 40 centimeters, so that negative pressure is sufficient to protect the operator from excess of fires or
dispersion of noxious gases;
- Supplied with electrical control panel with thermo-magnetic protection and command buttons; and,
- Equipped with pyrometers meters/controller of thermocouple temperature with chromium-aluminium,