Medical waste incinerator available

Waste type: health care waste

The Agent shall run a two days operation & maintenance training into the Biomedical technology personnel following installation & commissioning of this equipment.

Documentation:
Manual loading door
NB: The secondary combustion chamber have to ensure that the gas temp as measured against the inner wall in the secondary room & not in the fire zone, is less than 1100? C

Throughput: 50kg/hr at a nominal calorific value of 4,000kca/kg along with a mean bulk density of 120kg/m3 for general waste and 160kg/m3 for health care waste.
Thermal conductivity: 1.3W/mk
1 off combustion air supply fan and distribution system, automatic control
Waste density: 125 into 350Kg/M3
Limiting continuous service limit 1000? C
Burner: ordered for on/off operation
Chamber: should be refractory lined into the following standard;
The primary combustion chamber is the major structure of this incineration, fabricated from mild steel plate and stiffened with stainless steel sections.

it’s carried in the floor level on a substantial steel support frame.  Internally the casing is lined with calcium silicate insulation and a hot face combination of super duty brickwork or high strength castable.

Categories: