Incineration is the most obvious solution for total destruction of municipal waste, avoidingall the direct and indirect risks associated with other disposal methods.
Incineration perfectly fits into a trend of treating waste in a safe way, and if possible, at thesame place where it was generated to avoid cross-contamination risk and to keep waste treatment costs at acceptable level.
— Upgrade/Downgrade Burning Rate
Nanjing Clover Medical Technology Co.,Ltd.※ Main Feature:–– 3 Burning Chambers or A/B Main Burning Chamber— — Dual or 3 Italy Heater–– Burning Rate: 80-800kgs per hour–– Burning Chamber: 1.0M3-10.0 M3 ※ Optional Function/Parts/Material/ Burning Cost: — — Stainless Steel Smokeshaft — — Dry Smoke Filter Chamber— — Smokeshaft Elevation Homemade Made— — Semi-Automatic Waste Feeding— — 3-Section Damp Scrubber System— — Movable Platform Feeding Door— — Added Burner
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm Secondary Chamber 50L 110L 180L 280L 600L Smoke Filter Chamber Yes Yes Yes Yes Yes Feed Mode Manual Manual Manual Manual Manual Voltage 220V 220V 220V 220V 220V Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28 Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2 Temperature Monitor Yes Yes Yes Yes Yes Temperature Protection Yes Yes Yes Yes Yes Oil Tank 100L 100L 100L 100L 200L Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm Chimney 3Meter 3Meter 5Meter 5Meter 10Meter Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel 1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm Tel: +86 -25 -8461 0201
System purpose Infected clinical waste decontaminationUnit produced from stainless steel NecessaryDecontamination process is done in a shut system NecessaryWaste shredding within sterilization process NecessaryDecontamination technique 1No pressure; 2Moisture and also heat.Microbiological purification degree At least 6 log10Sterilization cycle temperature At the very least 1400CThe sanitation cycle time Not a lot more than 40 min.One cycle treated waste volume At the very least 100 litrųOne cycle treated waste weight At least 7 kgDecontaminated waste has to be 1Dry,2 Odorless,3 Not identifiableThe waste quantity reduction following treatment At least 70 percent The waste weight reduction following treatment At the very least 30% System control MicroprocessorControl panel Digital with touch screenNoise level At least 80 dBPower intake Not additional than 0,5 kWh/kgWater intake More than 0,003 m3/kgFiltering system 1At least two-stage carbon filters; 2HEPA filter.HEPA performance At least 95% Apparatus ability At the very least 15 kg/hr. Influence on the environment and employees Safe, environmentally friendlyDimensions ( for particular space) 90 size ( ± 10 ) x 150 deepness ( ± 10 ) x120 elevation ( ± 10)