and forced air conditioner stacks (or chimneys).
The charging system will consist of, as a minimum, a hopper for top feeding and automatically operated hydraulic
charging pliers or augur. To prevent warpage or excessive thermal expansion, a charger cooling system with either
atmosphere or water shall be provided.
Main combustion chamber shall be the rotary- or stationary fixed-hearth (or kiln) type incineration. Burner
and combustion air controls shall be fully automatic comprising , as a minimum, electronic ignition and all
required interlocks and safety devices to provide secure operation. The room and burner will be made to
maintain a minimum combustion temperature of 700 to 870 C (1300 to 1600 F), but will not to exceed 980
C (1800 F). The ash-removal system will consist of the automatic constant removal of the ash into a ashquench
pit in which cooled by water and eliminated by conveyor.