Basic Info.
Product Description
Technology Respond(FAQ)
Q: What is kind of waste can utilize in this equipment? A: This equipment to medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid gas and waste waste. GB18484-2001.
Q: Remedy capacity A: Average Ability calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not indicate any waste material. The animal/pet combustion rate around 2/3 of average capacity.
Clover incineration utilize time per day up to 24 hours. Between each feed/combustion time, there are approximately 0.5-1 hours cooling time plus time for feeding squander. Actual combustion time daily is around 16 hours. The life of incineration between 5-10 year based on utilize.
Generally, we proposal small lab, small clinic use capability under 20 kgs per hour. When incineration utilize in hospital, then please calculate the waste output around 2kgs per people every day. If there are 200 sickbed in the hospital, then which 's mean you need one incineration capability around 400kgs daily, change to capacity per hour is approximately 30-40 kgs per hour. According the performance time every day, waste material, budget, development, etc, you can use capacity from 30-50 kgs each hour incineration. *How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Assembly and Testing A: We supply all files and incinerations easy to setup and functionality. Client can send people come to our factory to learn installation and operation. Generally, we don’t send engineer to neighborhood site if not ask. The dispatch cost is additional based on order. The next combustion chamber: 1000-1200 centi degree. PLC mode based on model and order.
One individual can service 02 unit incinerations. Incinerators italy for medical waste, incinerations medical waste, incinirator, industrial incinerations china, insenorator, klarge garden incineration, laboratory animal incineration auction, The team should have fundamental electrician knowledge to operate/inspect/maintaince incineration/burner/blower based on operation user guider, and know threat of medical waste to protect employee self with necessary protection element.
Q: The Residency time in combustion chamber A: 02 sec.
Q: Operation and maintenance costs
A: Operation cost according to fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD per year maintenance according model, use situation.
One person can service 02 unit incinerations. Incinerators italy for medical waste, incinerations medical waste, incinirator, industrial incinerations china, insenorator, klarge garden incineration, lab animal incineration auction, The staff should have basic electrician knowledge to operate/inspect/maintaince incineration/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |