small scale incinerator

A change circuit breaker for each engine (ventilators and leftovers ).
? Insulate in fibrous panels:
OA sheath of all those gases burnt.
OBurner with fuel, mono-bloc casting guiding type with horizontal fire, lighting and security of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
oA burner of combustion of gases,
OA apparatus of injection of atmosphere allowing a total recombustion of gases,
Nature: Magnesium silicate.
? Burner of lighting of waste, with fuel, standard mono-bloc casting directing plunging fire, lighting and security of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
? Refractory concrete :
. Thickness    : ≥100 mm
OFrontage of loading door seals gone on hinges, wheel of screw plug, elastic joint, and stuffing insulating from refractory.
OCarcass in solid sheet steel with assistance of connection.
A timer with adjustable temporization for the regulation of each burner.
Plate of combustion in Carborundum, preventing the fixing of glass and slags

A room of article combustion of gases
A regulator with digital viewing for the temperature of combustion.
Controls and regulations:
OA apparatus of air ducts of cooling of waste gases,

Incinerators Biological waste disposal program (incineration)

Incinerator must satisfy the following criteria:

–       Combustion capacity (kW) = 581 +/-10%

–       Combustion capacity (kcal/h) = 500,000 +/-10%

–       Max. .

The incineration shall be completely self contained.

The incineration plant shall include a control panel for its own operation. On the control panel we shall have a visual screen of the room temperatures. This visual screen must control and track the incineration along with his performance.

Ability of jealousy in weight shall be 60 Kg/h.

The incineration should avoid the release of black smoke and dust that is fine, throughout the loadings.

It shall have the ability to reduce the quantity of wastes by 98%.

It shall have the ability to hold emission at the second burn with gas residence of not less than 2 seconds.

The incineration must be completely free from visible smoke as well as offensive odours.

1.0The primary ignition burner shall providing ignition of the waste to 850 °C and must switch off to conserve fuel.

the principal combustion chamber shall be built from thick steel plate along with the device is internally lined with a comprehensive layer of hote face refractory and higher efficiency insulation.

The Internal diameter of the Chimney at least:? 400 and its elevation: 8 m

The loudness of the combustion chamber at least: 1.200 L

The Dimension of the door for loading in cm at least: 70×70.

Burner operation should be Automatic On/Off
OA secondary injection of atmosphere to ensure oxygen content that is perfect.

A control box ensuring that the whole cycle of combustion.

Fan:
Fuel? : diesel

Manufacturer to provide  necessary information for the best of  the setup

The control panel shall have all proper audible and visual alerts to ensure safe operation.
Electric box

The secondary combustion chamber must destroy the contaminant product and must withstand to high temperature(1100 °C)

Process Filtering method: Scruber to be mentionned as optional

? Refractory concrete :
OComposition of the refractory;

A chamber of post combustion of gases
oA burner of combustion of gases,
oA device of injection of air allowing a total recombustion of gases,
oA device of air inlet of cooling of waste gases,
oA sheath of evacuation of the gases burnt.
oCarcass in strong sheet steel with support of connection.
oComposition of the refractory;
?Refractory concrete :
?Thickness    : ≥150 mm
?Nature: 65% of Al203
?Insulate in fibrous panel :
?Thickness: ≥85 mm
? Nature: Calcium
oBurner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
oA secondary injection of air to ensure perfect oxygen content.

A control box ensuring the complete cycle of combustion.

Fan:
oElectro-ventilator distributing the secondary air, the regulation of the air flow being carried out by valves and following the control of the automatic cycle.
Controls and regulations:
Control box watertight to dust, including:

A switch circuit breaker for each engine (ventilators and burners).
A timer with adjustable temporization for the regulation of each burner.
A regulator with digital watching for the temperature of combustion.
A regulator with digital watching for the temperature of post combustion.
Electric box

The secondary combustion chamber must destroy the contaminant product and must resist to high temperature(1100 °C)

Process Filtering system: Scruber to be mentionned as optional