small scale incinerator

The secondary combustion chamber must destroy the contaminant merchandise and must resist to high temperature(1100 °C)

Procedure purification system: Scruber to be mentionned as discretionary

A room of article combustion of gases
O Composition of the refractory;

? Refractory concrete :
. Thickness    : ≥100 mm
? Burner of lighting of waste, with gas, regular mono-bloc casting guiding  plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
Control box watertight to dust, including:

A switch circuit breaker for each engine (ventilators and burners).
? Refractory concrete :
A regulator with electronic watching for the warmth of article combustion.
Nature: Magnesium silicate.
OFrontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating from refractory.
OA apparatus of air inlet of cooling of waste gases,
? Nature: 65% of Al203
OA secondary injection of air to ensure oxygen content that is perfect.

A control box ensuring the complete cycle of combustion.

Fan:
?
OElectro-ventilator dispersing the secondary air, the regulation of the air flow being completed by valves and adhering to the control of the automatic cycle.
OPerfectly tight door to your manual loading of waste. The loading must be Manual, Batch Load
Fuel? : diesel

Manufacturer to give necessary information to your best of  the setup

The control panel will have all appropriate audible and visual alarms to ensure safe operation.

Incinerators Biological waste disposal system (incineration)

Incinerator must meet the following criteria:

—       Combustion capacity (kW) = 581 +/-10percent

—       Combustion ability (kcal/h) = 500,000 +/-10percent

—       Max. . 50% water content) = 100 +/-10percent

Further specifications will be given with the question.

The incineration shall be fully self contained.

The incineration plant will include a control panel for the operation. On the control panel we will have a visual display of their chamber temperatures. This visual display must control and monitor the incineration along with his performance.

Capacity of destruction in weight will be 60 Kg/h.

The incineration must prevent the discharge of black smoke and fine dust, throughout the loadings.

It will be able to decrease the volume of wastes from 98%.

It will be able to hold emission at the next burn with gas residence of not less than two seconds.

The incineration must be wholly free from visible smoke as well as offensive odours.

1.0the main ignition burner shall providing ignition of the waste to 850 °C and must switch off to conserve fuel.

the principal combustion chamber shall be built from heavy steel plate along with the unit is lined with a complete layer of hote face refractory and higher performance insulation.

The Inner Width of the Chimney at least:? 400 and its height: 8 m

The loudness of the combustion chamber at least: 1.200 L

The Dimension of the door for loading in cm at least: 70×70.

Burner operation ought to be Automatic On/Off

A control box ensuring the complete cycle of combustion.

Fan:
oElectro-ventilator distributing the secondary air, the regulation of the air flow being carried out by valves and following the control of the automatic cycle.
Controls and regulations:
Control box watertight to dust, including:

A switch circuit breaker for each engine (ventilators and burners).
A timer with adjustable temporization for the regulation of each burner.
A regulator with digital watching for the temperature of combustion.
A regulator with digital watching for the temperature of post combustion.
Electric box

The secondary combustion chamber must destroy the contaminant product and must resist to high temperature(1100 °C)

Process Filtering system: Scruber to be mentionned as optional