SOLID WASTE INCINERATOR

Main chamber — Consists of a monolithic high grade refractory concrete using high grade insulation financing,. Utilising a refractory hearth or equivalent for constant ash removal.

Secondary Chamber — Consists of high density, low thermal mass refractory ceramic fiber with an innovative low emissivity protective coating. Bio medical waste treatment plant ( Incineration )using panel.
Rating Temperature    1600 — 1800 deg. C
Refractory Material    Material *    Alumina ( 56 — 80% Actual )
Heat Insulation    Required for indoor installation
Delivery    Karachi Sea Port – Pakistan

The details of Components of incineration is as follows:
Thickness    25″ minimum
1: Main Controlled Air
Feeding & Ash Removing     System    Air Tight ventilating locked doors ( Feeding from Top will be preferred)
Heating Source    Natural Gas

Secondary Chamber    Temperature *    1100 — 1300 deg. C
Away — Gas System    Required
Main Chamber    Temperature Required*    800 — 1000 deg C.
System Status & Alarms    Required for all necessary parameters.
Insulation    Material    Ceramic Fiber

Secondary Chamber    Temperature *    1100 – 1300 deg. C
Heating Source    Natural Gas + Propane or Fuel Oil as an additional source
Off – Gas Residence Time     2 Seconds.
Refractory Material    Material *    Alumina ( 56 – 80 % Pure )
Lining *    SS 316L
Life Span *    10 – 15 years.
Rating Temperature    1600 – 1800 deg. C
Media    Slightly acidic
Insulation    Material    Ceramic Fiber
Thickness    25 “ minimum
Feeding & Ash Removing     System    Air Tight ventilating locked doors ( Feeding from Top will be preferred)
Spares    Required for 5 Years trouble free operation