Incinerator model A
Both primary and the secondary temperatures maintained until all the waste was completely combusted
Burn Rate – 150kg/hour minimum
One year Spare Parts Package for whole maintainability
Audible and/or visible alarm to remind the operator Once the secondary temperature falls to below the required temperature
Burn Rate 65kg/h minimum
HTW Incinerator model D
Burn Rate 250kg/h minimum
Burn Rate 50kg/h minimum
10m Hose Pipe, indicate length
Fuel Diesel/LPG/LNG, please indicate
General
One year Spare Parts Package for whole maintainability
Warranty, indicate no of years
Lot 5 — Mobile Incinerator
Power Supply for Control Box- 220V-240V 50Hz single phase
Secondary Chamber
toxic waste high temperature incinerations for the treatment of hazardous wastes. The waste will be mixed, such as medical, oily wastes, woods and lab wastes. Primary combustion
1000 Litre Fuel Tank + Pipe System, indicate volume
Added chimney expansion, indicate height
Added chimney expansion, indicate height
Power Supply for Control Box 220V-240V 50Hz single phase
Fuel Diesel/LPG/LNG, please indicate
Minimum operating temperature 1200°C, please indicate
One year Spare Parts Package for whole maintainability
Secondary Chamber
Burn Rate 100kg/h minimum
Warranty, indicate no of years
Incinerator model B
10m Hose Pipe, indicate length
10m Hose Pipe, indicate length
Added chimney expansion, indicate height
10m Hose Pipe, indicate length
Residence time in the secondary room not less than 2 seconds
One year Spare Parts Package for whole maintainability
Gas Retention Period 2 Seconds
Mobile Incinerator model E
Diesel/LPG/LNG burning primary combustion chamber/primary combustion zone
Minimum operating temperature 920 °C, please indicate
I000 Litre Fuel Tank + Pipe System, indicate volume
Secondary Chamber
Secondary Chamber
Minimum operating temperature 850 °C, please indicate
Fuel – Diesel/LPG/LNG, please indicate
Warranty, indicate no of years
Lot 7 — High Temperature Waste Mobile Incinerator
Chimney
1000 Litre Fuel Tank + Pipe System, indicate volume
Secondary combustion
Burn Rate 150kg/h minimum
Warranty, indicate no of years
Incinerator model C
Added chimney expansion, indicate height
Lot 6 — Mobile Incinerator
Secondary Chamber
Diesel/LPG/LNG, please indicate
Warranty, indicate no of years
Lot 4 — High Temperature Waste Incinerator
10m Hose Pipe, indicate length
Minimum operating temperature 850 °C, please indicate
Secondary Chamber
HTW Mobile Incinerator model G
Burn Rate 100kg/h minimum
Fuel – Diesel/LPG/LNG, please indicate
Minimum operating temperature 1200 °C, please indicate
Minimum exit velocity of the emissions not less than 10 metres/second
Added chimney expansion, indicate height
Fuel – Diesel/LPG/LNG, please indicate
Minimum operating temperature 920 °C, please indicate