Primarily for: solid and liquid waste Capacity range: 0,7 MW to 4,2 MW
Since the year 2004 company concentrates his activities in the area of the waste burning by


The purpose of the MultiZon units is to incinerate organic, combustible materials with a view to decreasing the vol¬ume and weight of materials, and to convert them sterile and disposable residual matter while complying fully with current environmental protection regulations.

Type of waste: Aggregate condition: solid and liquid
Heating value: 5 MJ/kg ¡Â 40 MJ/kg
Moisture: up to 30%
Density: 50 kg/m3 ¡Â 200 kg/m3
Power range Thermal capacity: 700 kW ¡Â 4¡¯200 kW
Throughput (with Hu of 15 MJ/kg) 1¡¯200 kg/day ¡Â 8¡¯000 kg/day


The key feature of the unit is the multizonal pyrolytic incineration of waste, particularly the separation of the differ¬ent stages involved in the incineration process.
Advantages:
acceptable emission standards maintained by the separation and control of the thermal decomposition and incineration process.
extremely low particulate emission due to non-turbulent combustion under sub stoichiometric conditions.
elimination of contaminants in the flue gas by complete oxidation of combustible gases in the thermal re¬actor.
complete combustion of the waste, resulting in sterile ash.
stable process which can accommodate variations in waste make-up.
volume and mass reduction of approx. 95%, thereby lower disposal costs.
wide range of unit sizes giving waste throughputs of 300 to 10¡¯000 kg per day.
utilization of the valuable heat form the waste to produce hot water or steam, giving very attractive pay¬back periods.

Independence of operation
The MultiZon enables localized incineration to be carried out as and when required. This gives independence from outside services and eliminates disposal costs and waste transport problems. In addition the MultiZon system en¬ables the energy in the waste to be utilized to produce hot water, steam or thermo oil, resulting in high financial benefits.
Multiple applications
The MultiZon equipment is suitable for the incineration of common industrial waste, hospital waste and special waste such as tyres, solvents, textiles and various plastics. Even the recovery of precious metals, e.g. silver from films, is possible.


The essential requirements for trouble free burning of waste are:
Heating, drying and degassing of waste in the low temperature chamber.
Mixing, igniting and complete oxidation of the gases in the thermal reactor.

Individual monitoring and control of each operation gives good incineration performance, virtually independent of the waste composition, with smoke free operation and uncontaminated gas emission. The waste is heated to the required ignition temperature. Only sufficient oxygen is admitted to give the necessary reaction heat to maintain the thermal decomposition and degassing in the waste. The gas released contains a large quantity of flammable, energy-rich constituents. The gas passes to the mixing zone in the thermal reactor and secondary air is introduced to give an ignitable mixture. This mixture then com¬bines with tertiary air and burns out the ignition and reaction zones with a consequent rise in temperature.

GG JOSEPH EGLI AG

CHARGING

Various charging systems are available to comply with the type of waste.



INCINERATION


Primary chamber GG7 Primary chamber GG24 Ash-ram with doubble stocking head

POST COMBUSTION



Thermal reactor ¨C the key component
This unit is made up of a number of cylindrical steel sections with internal refractory lining. This allows the reactor volume to be adjusted to give appropriate residence times for different waste. The temperature in the internal reactor depends on the quality of the gas from the low temperature chamber and up to 1400¡ãC can be reached.
ASH REMOVAL

Screw conveyor Metallic belt conveyor Sterile ash
Ash and slag fall from the last step into a container. They are then taken continuously by conveyor and transported to movable ash container.
GG JOSEPH EGLI AG 5
HEAT RECOVERY


The hot gases can be drawn through a waste heat boiler to produce hot water, steam or thermo oil.
FLUE GAS TREATMENT
For different waste, different legal requirement and different climatic conditions we can provide different flue gas treatments to optimize efficiency and operating cost.

Dry adsorption by bag filter Wet venturi and scrubber Combined wet and dry system
JOSEPH EGLI AG GG
CONTROL SYSTEM


Control system Process Visualization Continuous monitoring system

Model
Capacity


Throughput volume kg/h
Max. daily capacity to/Tag
Consumption (Details are based on experience values and depend very much on waste properties)

Alternative: natural gas (G20) Nm3/h
Adsorbent kg/h
The technical data for our standard systems were recorded at the time of printing. They are, however, subject to continuous modification and cannot be guaranteed.
The data are based on waste with a lower heating value of 15 MJ/kg an 10 % moisture.
All consumption data are empirical values, highly dependent on the composition of waste and operating conditions and are therefore only indicative and not guaranteed.

WORLDWIDE OVER 170 „GG¡° INCINERATORS IN OPERATION


¡¡

 

                
¡¡ ¡¡

¡¡

¡¡

¡¡

¡¡
¡¡ Medical Incinerators,30 Kgs Burn Rate Incinerator,Burner of Medical Waste Automatically,
Gas Fired Incinerator,Hospital Medical Waste Incinerator,Incinerators for Medical Waste Disposal,Industrial Incinerator,
Medical Incinerators Capacity Calculations,Msw Incinerator Msw1000,Poultry Incinerator,Small Medical Waste Incinerator,
Temperature Control Incinerator,Diesel and Gas Incinerator 50 Kg Per Hour
¡¡
¡¡ ¡¡ ¡¡
¡¡ ¡¡ ¡¡
¡¡ ¡¡ ¡¡