Day: July 16, 2019

Incineration System for Medical Waste (Capacity 6 Tons Per day); Incineration System for Medical Waste (Capacity 12 Tons Per day); Polluted air control technology i.e. ( Wet scrubber, bags); Flue gas treatment system (gas emission technology). What is the Gases Emission Standard you are using? What is the fuel you are using/recommending in your equipment? medical hospital incinerator Capacity: 30 Kg. destruction capacity: 3.000 kcal/kg diesel. max consume: 2.5 gal per hour. 1 camera: 1 burner capacity: 80.00 kcal Type: K (Ni-CrNi) enter size: 500x500mm ash door: 190 x 250mm 2 camera: 1 burner capacity: 80.000 kcal. Air conbustion: 0.5 HP Type: K (Ni-CrNi) Temperature 1 camera: Normal work temperature: 750 -900? C, Max temperature: 1000? C. 2 camera: Normal work temperature: 950-1000? C. Max temperature: 1100? C. Chimey: minimum 3 meters Controlator ciclo control 110-120 v / 60 Hz.
Version , the entire carcass of animals ( cattle , horses , Sheep, pigs , etc.) , as well as biologically hazardous waste Products in the fuel stove . ? Opening Doors – the closure and fixation automated system , Which are managed remotely by the operator . ? designed to work in long mode and fast Action ( Quick Start EP – i)  Fully mobile – mounted on wheeled chassis Even during the operation . Incinerators must be provided As standard equipment a special truck  air retention for at least 2 seconds at a temperature of less than 850C, the combustion In order to achieve the proper effect. must be a two-chamber incinerators, primary and secondary Fuel stoves The waste products to reduce the initial volume Possible to minimize (approximately 5% sterile ash Form). Incinerators should be provided in the fuel tank (diesel ) The minimum capacity of the animal carcass incinerator The destruction of 1000 kg / hour. Incinerator capacity is calculated 8MJ/kg- material and 60 % humidity. It must be possible to use the incinerator +40  C to – 15 0C Temperature and 5% – 95% – of moisture conditions. ? PLC controller and a built-in temperature panelita complete Automatic control, a control computer, which is stored   Information on the variation of temperature with respect to time and Graphic images. must have fuel with automatic control and malfunction Detection system. ?the ability to pre- warm-up , body waste burning on and off Consistency is independent of the first and secondary chambers. ensuring the incinerator with electricity , it Must be installed on the generator. clean the incinerator should be simple tools , Without using any additional equipment Incinerator to burn 25 to 30 kg/hr of waste Double Chamber Low maintenance with diesel filled and no more than 15amp 220 C 250 V KW must be stated. Onboard or inbuilt fuel storage tank, no more than 12L of diesel/hr Simple start for less operator training skills System to accommodate low power and frequent supply problems
Recent Posts